890 research outputs found

    The effect of the displacement damage on the Charge Collection Efficiency in Silicon Drift Detectors for the LOFT satellite

    Get PDF
    The technology of Silicon Drift Detectors (SDDs) has been selected for the two instruments aboard the Large Observatory For X-ray Timing (LOFT) space mission. LOFT underwent a three year long assessment phase as candidate for the M3 launch opportunity within the "Cosmic Vision 2015 -- 2025" long-term science plan of the European Space Agency. During the LOFT assessment phase, we studied the displacement damage produced in the SDDs by the protons trapped in the Earth's magnetosphere. In a previous paper we discussed the effects of the Non Ionising Energy Losses from protons on the SDD leakage current. In this paper we report the measurement of the variation of Charge Collection Efficiency produced by displacement damage caused by protons and the comparison with the expected damage in orbit.Comment: 17 pages, 7 figures. Accepted for publication by Journal of Instrumentatio

    Musculoskeletal MRI at 7 T: do we need more or is it more than enough?

    Get PDF
    Ultra-high field magnetic resonance imaging (UHF-MRI) provides important diagnostic improvements in musculoskeletal imaging. The higher signal-to-noise ratio leads to higher spatial and temporal resolution which results in improved anatomic detail and higher diagnostic confidence. Several methods, such as T2, T2*, T1rho mapping, delayed gadolinium-enhanced, diffusion, chemical exchange saturation transfer, and magnetisation transfer techniques, permit a better tissue characterisation. Furthermore, UHF-MRI enables in vivo measurements by low-γ nuclei (23Na, 31P, 13C, and 39K) and the evaluation of different tissue metabolic pathways. European Union and Food and Drug Administration approvals for clinical imaging at UHF have been the first step towards a more routinely use of this technology, but some drawbacks are still present limiting its widespread clinical application. This review aims to provide a clinically oriented overview about the application of UHF-MRI in the different anatomical districts and tissues of musculoskeletal system and its pros and cons. Further studies are needed to consolidate the added value of the use of UHF-MRI in the routine clinical practice and promising efforts in technology development are already in progress

    Measurement of the effect of Non Ionising Energy Losses on the leakage current of Silicon Drift Detector prototypes for the LOFT satellite

    Full text link
    The silicon drift detectors are at the basis of the instrumentation aboard the Large Observatory For x-ray Timing (LOFT) satellite mission, which underwent a three year assessment phase within the "Cosmic Vision 2015 - 2025" long-term science plan of the European Space Agency. Silicon detectors are especially sensitive to the displacement damage, produced by the non ionising energy losses of charged and neutral particles, leading to an increase of the device leakage current and thus worsening the spectral resolution. During the LOFT assessment phase, we irradiated two silicon drift detectors with a proton beam at the Proton Irradiation Facility in the accelerator of the Paul Scherrer Institute and we measured the increase in leakage current. In this paper we report the results of the irradiation and we discuss the impact of the radiation damage on the LOFT scientific performance.Comment: 21 pages, 7 figures, 2 tables. Accepted for publication by Journal of Instrumentation (JINST

    Hyper-velocity impact test and simulation of a double-wall shield concept for the Wide Field Monitor aboard LOFT

    Full text link
    The space mission LOFT (Large Observatory For X-ray Timing) was selected in 2011 by ESA as one of the candidates for the M3 launch opportunity. LOFT is equipped with two instruments, the Large Area Detector (LAD) and the Wide Field Monitor (WFM), based on Silicon Drift Detectors (SDDs). In orbit, they would be exposed to hyper-velocity impacts by environmental dust particles, which might alter the surface properties of the SDDs. In order to assess the risk posed by these events, we performed simulations in ESABASE2 and laboratory tests. Tests on SDD prototypes aimed at verifying to what extent the structural damages produced by impacts affect the SDD functionality have been performed at the Van de Graaff dust accelerator at the Max Planck Institute for Nuclear Physics (MPIK) in Heidelberg. For the WFM, where we expect a rate of risky impacts notably higher than for the LAD, we designed, simulated and successfully tested at the plasma accelerator at the Technical University in Munich (TUM) a double-wall shielding configuration based on thin foils of Kapton and Polypropylene. In this paper we summarize all the assessment, focussing on the experimental test campaign at TUM.Comment: Proc. SPIE 9144, Space Telescopes and Instrumentation 2014: Ultraviolet to Gamma Ray, 91446

    Simulations of the X-ray imaging capabilities of the Silicon Drift Detectors (SDD) for the LOFT Wide Field Monitor

    Full text link
    The Large Observatory For X-ray Timing (LOFT), selected by ESA as one of the four Cosmic Vision M3 candidate missions to undergo an assessment phase, will revolutionize the study of compact objects in our galaxy and of the brightest supermassive black holes in active galactic nuclei. The Large Area Detector (LAD), carrying an unprecedented effective area of 10 m^2, is complemented by a coded-mask Wide Field Monitor, in charge of monitoring a large fraction of the sky potentially accessible to the LAD, to provide the history and context for the sources observed by LAD and to trigger its observations on their most interesting and extreme states. In this paper we present detailed simulations of the imaging capabilities of the Silicon Drift Detectors developed for the LOFT Wide Field Monitor detection plane. The simulations explore a large parameter space for both the detector design and the environmental conditions, allowing us to optimize the detector characteristics and demonstrating the X-ray imaging performance of the large-area SDDs in the 2-50 keV energy band.Comment: Proceedings of SPIE, Vol. 8443, Paper No. 8443-210, 201

    Radiation tests of the Silicon Drift Detectors for LOFT

    Full text link
    During the three years long assessment phase of the LOFT mission, candidate to the M3 launch opportunity of the ESA Cosmic Vision programme, we estimated and measured the radiation damage of the silicon drift detectors (SDDs) of the satellite instrumentation. In particular, we irradiated the detectors with protons (of 0.8 and 11 MeV energy) to study the increment of leakage current and the variation of the charge collection efficiency produced by the displacement damage, and we "bombarded" the detectors with hypervelocity dust grains to measure the effect of the debris impacts. In this paper we describe the measurements and discuss the results in the context of the LOFT mission.Comment: Proc. SPIE 9144, Space Telescopes and Instrumentation 2014: Ultraviolet to Gamma Ray, 91446

    The X-Gamma Imaging Spectrometer (XGIS) onboard THESEUS

    Get PDF
    A compact and modular X and gamma-ray imaging spectrometer (XGIS) has been designed as one of the instruments foreseen on-board the THESEUS mission proposed in response to the ESA M5 call. The experiment envisages the use of CsI scintillator bars read out at both ends by single-cell 25 mm 2 Silicon Drift Detectors. Events absorbed in the Silicon layer (lower energy X rays) and events absorbed in the scintillator crystal (higher energy X rays and Gamma-rays) are discriminated using the on-board electronics. A coded mask provides imaging capabilities at low energies, thus allowing a compact and sensitive instrument in a wide energy band (~2 keV up to ~20 MeV). The instrument design, expected performance and the characterization performed on a series of laboratory prototypes are discussed.Comment: To be published in the Proceedings of the THESEUS Workshop 2017 (http://www.isdc.unige.ch/theseus/workshop2017.html), Journal of the Italian Astronomical Society (Mem.SAIt), Editors L. Amati, E. Bozzo, M. Della Valle, D. Gotz, P. O'Brien. Details on the THESEUS mission concept can be found in the white paper Amati et al. 2017 (arXiv:171004638) and Stratta et al. 2017 (arXiv:1712.08153

    EXPERIENCE IN MOBILE LASER SCANNING BY MEANS OF LYNX SYSTEM IN L’AQUILA CITY

    Get PDF
    The terrestrial laser scanner is an efficient topographical instrumentation used to acquire a redundant number of points distributed over a physical surface. The goal of laser scanning is the definition of very accurate models of the studied areas. In this way, deformations or changes can be monitored by means of repeated surveys in different epochs [Pesci et al., 2005; 2007]. The laser signal is characterized by highly collimated, monochromatic, and coherent radiation that is well suitable for very short impulse generation in the nanosecond scale. The operating methodology of a time-of-flight laser scanner is similar to a laser range-finder, measuring the time it takes a laser pulse to travel from a transmitter to the surface surveyed, and back to a detector device. The range d is computed using the relation d = ct / 2, where t is the time of flight and c is the speed of light. The advantage of this instruments is the laser beam deflection over a very accurate angular grid, that can be obtained by oscillating and rotating mirrors, thus providing a wide coverage area between adjacent points. Each point is collected into a local reference system consisting of the origin at the instrument sensor, well-known angular parameters, and very accurate measurements of range. Together with point coordinates (x, y, z) , radiometric values related to the surveyed object’s reflectivity can be calculated from returned signal energy. The maximum measurable range depends on the illuminated material roughness and color, and the laser wavelength [Fidera et al. 2004, Pesci and Teza, 2008]. Divergence values for new generation long-range scanners are extremely reduced, illuminating very small surface elements for each shot. The spot dimension increases linearly with the distance, and is always greater than the lower limit of the instantaneous field of view (IFOV) due to physical diffraction. Effective laser scanner characteristics are defined by a set of parameters, including: range resolution (depending on telemeter efficiency), single point measurement accuracy (depending on the internal electronic device, signal-to-noise ratio and critical time needed for pulse recognition), beam divergence (which defines the IFOV, depending on laser wavelength), and minimum angular step (depending on the internal mirrors calibrated system) [Wehr and Lohr 1999]. Overlap is the laser scanning strategy that can reduce errors, because redundant points are acquired belonging to the same illuminated area. A common overlap is obtained by fixing the ratio between spot dimension (the area illuminated by a single pulse with a given divergence) and angular step so that a given point is measured 10 times. For instance, if the divergence is 3 mrad and angular variation about 0.3 mrad, at 100 m distance, an element included in a 3 cm area is observed 10 times. The final result of a laser scanner application is a very dense point cloud, with radiometric reflectivity data for each point

    Humeral greater tuberosity osteolysis as a complication of intraosseous calcification migration: Natural history depicted by imaging

    Get PDF
    Migration of calcification within the bone leading to greater tuberosity osteolysis is a peculiar complication of the calcifying tendinitis of the rotator cuff. The case of a 38-year-old woman complaining of right shoulder pain, which had been going on for one year, is hereby described. The evolution of the infraspinatus tendon calcifying tendinitis leading to osteolysis of the greater tuberosity of the humerus is depicted by imaging and, particularly, by the MR and CT features changing over time. In this paper we focus on the importance of both MR and CT exams in the diagnostic process of the different phases of the disease. The correlation between clinical symptoms and imaging features is also helpful for imaging interpretation: the most painful phase corresponds to the migration of the calcification, whereas pain tends to decrease when the osteolysis develops. Awareness of the existence of this condition may prevent unnecessary invasive procedures. (www.actabiomedica.it)
    • …
    corecore